Contractor Pricing Available | Contact Our Team at sales@bypassfeeder.com
for Exclusive Reseller Discounts
Need Help Choosing the Right Feeder?
Speak with Our Technical Experts at (623) 624-5662 Today

ATTENTION CONTRACTORS: contact sales@bypassfeeder.com for additional resale discounts



J.L. Wingert DB-2HD Dome Bottom Bypass Feeder

Sale price $545.33 Regular price $661.00

REQUEST A QUOTE

Product Overview

The J.L. Wingert DB-2HD Dome Bottom Bypass Feeder is a compact and efficient chemical feed solution designed for closed-loop HVAC systems, boiler systems, chilled water applications, and industrial water treatment programs. Built for reliable chemical treatment and system maintenance, this feeder allows operators to introduce water treatment chemicals directly into a circulating system while maintaining safe and efficient operation. Commonly used as a chemical shot feeder, the DB-2HD helps support corrosion prevention, scale control, and overall system performance in commercial and industrial environments.

Designed with a durable carbon steel vessel and dome-bottom construction, the DB-2HD offers long-lasting reliability while simplifying chemical treatment procedures for facility managers and water treatment professionals.

Why Choose the J.L. Wingert DB-2HD?

Proper chemical treatment is essential for protecting closed-loop systems from corrosion, scale buildup, biological growth, and reduced efficiency. The DB-2HD provides a safe and convenient method for introducing treatment chemicals into the system without requiring extensive downtime or complex installation.

Key Benefits

✔ Easy chemical injection for closed-loop systems

✔ Supports corrosion and scale control programs

✔ Compact design for smaller mechanical rooms

✔ Durable carbon steel construction

✔ Simple maintenance and operation

✔ Suitable for heating and cooling systems

✔ Helps extend equipment lifespan

✔ Designed for commercial and industrial applications

Key Features

Dome Bottom Design

The dome-bottom vessel design promotes effective drainage and cleaning while reducing the accumulation of residual chemicals and sediment within the feeder.

Heavy-Duty Carbon Steel Construction

Manufactured by J.L. Wingert, the DB-2HD is engineered for long-term use in demanding water treatment environments where durability and reliability are critical.

Convenient Quarter-Turn Closure

The feeder features a quick-access quarter-turn closure that allows operators to safely add treatment chemicals while minimizing maintenance time.

Supports Water Treatment Programs

The DB-2HD helps maintain proper water chemistry by providing a dedicated point for introducing treatment chemicals into closed-loop systems.

Compact Installation Footprint

Its compact design makes it an excellent choice for smaller commercial facilities and mechanical rooms where space is limited.

Common Applications

The J.L. Wingert DB-2HD Dome Bottom Bypass Feeder is commonly used in:

HVAC Systems

  • Chilled water systems
  • Hot water systems
  • Hydronic heating loops
  • Closed-loop HVAC applications

Boiler Systems

  • Steam boiler water treatment
  • Hot water boiler systems
  • Condensate treatment programs

Commercial Facilities

  • Office buildings
  • Schools and universities
  • Healthcare facilities
  • Hotels and hospitality properties

Industrial Applications

  • Manufacturing plants
  • Process water systems
  • Industrial cooling systems

Technical Specifications

Specification Details
Model DB-2HD
Manufacturer J.L. Wingert
Feeder Type Dome Bottom Bypass Feeder
Fill Capacity 2 Gallons
Maximum Working Pressure 200 PSI
Maximum Operating Temperature 200°F
Vessel Construction Carbon Steel
Inlet Connection 3/4" FNPT
Outlet Connection 3/4" FNPT
Closure Type Quarter-Turn Closure

Compare J.L. Wingert Dome Bottom Bypass Feeders

Feature DB-2HD DB-5HD DB-12HD
Fill Capacity 2 Gallons 5 Gallons 12 Gallons
Max Pressure 200 PSI 200 PSI 200 PSI
Max Temperature 200°F 200°F 200°F
Construction Carbon Steel Carbon Steel Carbon Steel
Connection Size 3/4" FNPT 3/4" FNPT 3/4" FNPT
Recommended Application Small Systems Medium Systems Large Systems
Chemical Feed Capability Yes Yes Yes

Which Bypass Feeder Should You Choose?

System Size Recommended Model
Small Closed-Loop Systems DB-2HD
Medium Commercial Facilities DB-5HD
Large Commercial & Industrial Systems DB-12HD


The DB-2HD is ideal for smaller systems where reliable chemical treatment is required without the need for a larger feeder capacity.

How a Bypass Feeder Works

A bypass feeder is installed on a side-stream loop connected to a closed-loop water system. Treatment chemicals are placed inside the feeder vessel, and system water circulates through the unit, gradually dissolving and distributing the chemicals throughout the system.

This controlled treatment process helps maintain proper water chemistry while reducing corrosion, scaling, and other issues that can negatively impact equipment performance and system efficiency.

Ideal For

This feeder is commonly selected by:

  • Water treatment professionals
  • HVAC contractors
  • Facility managers
  • Building engineers
  • Mechanical contractors
  • Industrial maintenance teams

Need Help Selecting the Right Bypass Feeder?

Not sure if the J.L. Wingert DB-2HD is the best fit for your application?

Our specialists can help you:

  • Select the proper feeder size
  • Determine treatment requirements
  • Recommend compatible accessories
  • Provide volume pricing
  • Answer installation questions

👉 Request a Quote Today

Or call (623) 624-5662 to speak with a product specialist.

Frequently Asked Questions

1. What is the purpose of the J.L. Wingert DB-2HD?

The DB-2HD is used to introduce water treatment chemicals into closed-loop systems to help control corrosion, scale formation, and other water quality issues.

2. What size systems is the DB-2HD best suited for?

Its 2-gallon capacity makes it ideal for smaller HVAC systems, boiler systems, and commercial water treatment applications.

3. Can the feeder be used in chilled water systems?

Yes. The DB-2HD is commonly used in chilled water, hot water, and hydronic heating systems.

4. What is the maximum operating pressure?

The feeder is rated for operation up to 200 PSI.

5. Why is chemical treatment important in closed-loop systems?

Proper treatment helps prevent corrosion, scale buildup, biological growth, and equipment damage while improving overall system efficiency.

Download Resources:

Click Here for the Brochure

Click Here for the Manual

Click Here for the Specifications