J. L. Wingert GL50-E1-1 Economy 55 Gallon Glycol Feed System with Low Level Control

Sale price $3,763.65 Regular price $4,562.00

REQUEST A QUOTE

Product Overview

The J. L. Wingert GL50-E1-1 Economy 55 Gallon Glycol Feed System with Low Level Control is designed to automatically maintain proper fluid levels and system pressure in closed-loop heating, cooling, and process systems. Featuring a 55-gallon polyethylene tank, integrated pump assembly, and low-level control functionality, this glycol feed system provides reliable glycol and water replenishment while helping protect equipment from air intrusion, pressure loss, corrosion, and costly downtime.

Ideal for commercial HVAC systems, chilled water loops, hydronic heating systems, and industrial process applications, the GL50-E1-1 delivers dependable performance while reducing maintenance requirements and supporting long-term system efficiency.

Why Choose the J. L. Wingert GL50-E1-1?

Maintaining proper pressure and fluid volume is critical for the performance and protection of closed-loop systems. The GL50-E1-1 automatically replenishes fluid as needed, helping facility operators maintain optimal operating conditions while reducing manual intervention.

Key Benefits

✔ Automatically maintains system pressure

✔ Helps prevent air infiltration and system corrosion

✔ Reduces maintenance and monitoring requirements

✔ Supports glycol and water treatment programs

✔ Integrated low-level protection control

✔ Durable 55-gallon polyethylene tank

✔ Suitable for commercial and industrial applications

✔ Reliable operation in closed-loop systems

Key Features

55-Gallon Polyethylene Reservoir

The heavy-duty reservoir provides ample storage capacity for glycol solutions and make-up water, reducing refill frequency while supporting continuous operation.

Automatic Fluid Replenishment

The integrated pump system automatically delivers fluid to maintain desired system pressure and volume levels, helping eliminate pressure fluctuations that can affect system performance.

Low-Level Control Protection

The built-in low-level control helps protect equipment by alerting operators when fluid levels become low, reducing the risk of pump damage and operational interruptions.

Durable Industrial Construction

Engineered by J. L. Wingert, the GL50-E1-1 is built to withstand demanding commercial and industrial operating environments while delivering long-term reliability.

Ideal for Closed-Loop Applications

This system is specifically designed for hydronic heating, chilled water, cooling, and process systems where maintaining proper fluid levels is essential.

Common Applications

The GL50-E1-1 is commonly used in:

Commercial HVAC Systems

  • Chilled water systems
  • Heating water systems
  • Hydronic loops
  • Heat pump systems

Industrial Process Systems

  • Process cooling applications
  • Manufacturing facilities
  • Industrial temperature control systems

Institutional Facilities

  • Hospitals
  • Universities
  • Schools
  • Government buildings

Mechanical Contractor Projects

  • New installations
  • Retrofit projects
  • System upgrades

Technical Specifications

Specification Details
Model GL50-E1-1
Manufacturer J. L. Wingert
Tank Capacity 55 Gallons
Tank Material Polyethylene
Control Type Low Level Control
Application Closed-Loop Systems
Fluid Type Glycol Solutions & Water
Installation Commercial & Industrial Systems
Operation Automatic Make-Up System

Compare J. L. Wingert Glycol Feed Systems

Feature GL15-E1-1 GL30-E1-1 GL50-E1-1
Tank Capacity 15 Gallons 30 Gallons 55 Gallons
Low Level Control Yes Yes Yes
Automatic Feed Operation Yes Yes Yes
Reservoir Material Polyethylene Polyethylene Polyethylene
Recommended Application Small Systems Medium Systems Large Systems
Commercial HVAC Use Yes Yes Yes
Industrial Applications Limited Moderate Extensive

Which Glycol Feed System Is Right for Your Facility?

System Size Recommended Model
Small Hydronic Systems GL15-E1-1
Medium Commercial Buildings GL30-E1-1
Large Commercial Facilities GL50-E1-1
Industrial Process Systems GL50-E1-1


The GL50-E1-1 is the preferred choice for larger facilities requiring increased fluid storage capacity and dependable automatic replenishment.

How a Glycol Feed System Works

A glycol feed system automatically monitors and maintains fluid levels within a closed-loop system. When pressure drops due to fluid loss, maintenance activities, or system expansion and contraction, the feed system introduces additional glycol solution or water to restore proper operating conditions.

By maintaining consistent pressure and fluid volume, the system helps improve efficiency, reduce corrosion risks, and protect valuable HVAC and process equipment.

Ideal For

This model is commonly selected by:

  • Mechanical contractors
  • Facility managers
  • HVAC professionals
  • Building engineers
  • Industrial maintenance departments
  • Water treatment specialists

Need Help Selecting the Right Glycol Feed System?

Not sure if the GL50-E1-1 is the best option for your application?

Our specialists can help you:

  • Select the correct system size
  • Determine fluid capacity requirements
  • Recommend accessories
  • Provide volume pricing
  • Answer installation questions

👉 Request a Quote Today

Or call (623) 624-5662 to speak with a product specialist.

Frequently Asked Questions

1. What is the purpose of a glycol feed system?

A glycol feed system automatically maintains fluid levels and pressure in closed-loop systems by supplying glycol solution or make-up water when needed.

2. Why is low-level control important?

Low-level control helps prevent pump damage and operational issues by alerting operators when reservoir fluid levels become too low.

3. Can this system be used with glycol solutions?

Yes. The GL50-E1-1 is specifically designed for glycol-based heating and cooling systems as well as water-based closed-loop systems.

4. What size facility is this model best suited for?

The 55-gallon capacity makes it ideal for larger commercial buildings, institutional facilities, and industrial applications.

5. Does the system require manual monitoring?

The automatic feed functionality significantly reduces manual monitoring requirements while helping maintain consistent operating conditions.

Download Resources:

Click here for the data sheet

Click here for the brochure

Click here for instruction sheet