{"product_id":"j-l-wingert-gl50-h1-1-high-temperature-55-gallon-glycol-feed-system-with-low-level-control","title":"J. L. Wingert GL50-H1-1 High Temperature 55 Gallon Glycol Feed System with Low Level Control","description":"\u003ch2\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eJ. L. Wingert GL50-H1-1 High Temperature 55 Gallon Glycol Feed System with Low Level Control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is engineered to maintain proper fluid levels and system pressure in high-temperature closed-loop heating and process systems. Featuring a durable 55-gallon reservoir, automatic feed operation, and integrated low-level control, this system helps ensure reliable performance while protecting valuable equipment from pressure loss, air infiltration, and fluid depletion. Designed for demanding commercial and industrial applications, the GL50-H1-1 serves as a dependable \u003c\/span\u003e\u003ca href=\"https:\/\/bypassfeeder.com\/collections\/glycol-feeders\"\u003eglycol feeder tank\u003c\/a\u003e\u003cspan\u003e solution for facilities requiring continuous fluid management and system protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy Choose the J. L. Wingert GL50-H1-1?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHigh-temperature systems require precise pressure and fluid level control to maintain efficiency and prevent costly downtime. The GL50-H1-1 automatically replenishes fluid as needed, helping operators maintain stable operating conditions while reducing manual maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Designed for high-temperature applications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Automatically maintains system pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Integrated low-level protection control\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Reduces the risk of air intrusion\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Supports glycol treatment programs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Durable 55-gallon storage capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Suitable for commercial and industrial systems\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e✔ Helps extend equipment life and reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eHigh-Temperature System Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GL50-H1-1 is specifically designed for applications where elevated operating temperatures require dependable make-up fluid management and pressure maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e55-Gallon Reservoir Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe large-capacity reservoir provides ample storage for glycol solutions, helping reduce refill frequency while supporting continuous system operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAutomatic Fluid Replenishment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated feed assembly automatically introduces fluid when pressure drops below desired levels, helping maintain proper system performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLow-Level Control Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBuilt-in low-level controls provide additional system protection by notifying operators when fluid levels become low, helping prevent interruptions and equipment damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommercial and Industrial Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eManufactured by J. L. Wingert, this feed system is engineered for long service life in demanding heating and process environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GL50-H1-1 is commonly installed in:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommercial Heating Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eHydronic heating systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClosed-loop hot water systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDistrict heating applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBoiler support systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Process Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eProcess heating applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManufacturing facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial temperature control systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnergy facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstitutional Buildings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eHospitals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUniversities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGovernment facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial campuses\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Contractor Projects\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eNew system installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFacility upgrades\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment retrofits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGL50-H1-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJ. L. Wingert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Temperature Glycol Feed System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTank Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 Gallons\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReservoir Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyethylene\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Level Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClosed-Loop Heating \u0026amp; Process Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFluid Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGlycol Solutions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Feed System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eCompare J. L. Wingert High Temperature Glycol Feed Systems\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGL15-H1-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGL30-H1-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGL50-H1-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTank Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 Gallons\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 Gallons\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 Gallons\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Temperature Design\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow Level Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Feed Operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommercial Applications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Applications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModerate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtensive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Facility Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSmall\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMedium\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLarge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eWhich Model Is Right for Your Facility?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSmall Heating Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGL15-H1-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMedium Commercial Buildings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGL30-H1-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLarge Commercial Facilities\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGL50-H1-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Process Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGL50-H1-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e\u003cbr\u003eThe GL50-H1-1 is ideal for facilities requiring larger fluid storage capacity and dependable automatic replenishment for high-temperature operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eHow a High Temperature Glycol Feed System Works\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA glycol feed system continuously monitors pressure within a closed-loop heating system. When fluid loss or pressure reduction occurs, the feed unit automatically introduces additional glycol solution to restore proper operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis automated process helps reduce manual intervention, maintain system efficiency, and protect equipment from damage caused by insufficient fluid levels or pressure fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis system is commonly selected by:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMechanical contractors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHVAC professionals\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFacility managers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilding engineers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial maintenance teams\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess heating specialists\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eNeed Help Selecting the Right Glycol Feed System?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNot sure if the GL50-H1-1 is the best fit for your application?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur specialists can help you:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eDetermine proper system sizing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRecommend compatible accessories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvide volume pricing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAssist with installation questions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupport maintenance planning\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e👉 \u003ca href=\"https:\/\/bypassfeeder.com\/pages\/inhibited-ethylene-and-propylene-glycol\" class=\"text-link\"\u003eRequest a Quote Today\u003c\/a\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eOr call \u003ca href=\"tel:(623)%20624-5662\" class=\"text-link\"\u003e\u003cstrong\u003e(623) 624-5662\u003c\/strong\u003e\u003c\/a\u003e to speak with a product specialist.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/FAQPage\" itemscope=\"\"\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Question\" itemprop=\"mainEntity\" itemscope=\"\"\u003e\n\u003ch3 itemprop=\"name\"\u003e\u003cstrong\u003e1. What is the purpose of the GL50-H1-1?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Answer\" itemprop=\"acceptedAnswer\" itemscope=\"\"\u003e\n\u003cp itemprop=\"text\"\u003eThe GL50-H1-1 automatically maintains fluid levels and pressure within high-temperature closed-loop systems, helping improve reliability and operational efficiency.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Question\" itemprop=\"mainEntity\" itemscope=\"\"\u003e\n\u003ch3 itemprop=\"name\"\u003e\u003cstrong\u003e2. What makes this a high-temperature model?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Answer\" itemprop=\"acceptedAnswer\" itemscope=\"\"\u003e\n\u003cp itemprop=\"text\"\u003eThis system is specifically designed to support applications operating at elevated temperatures where dependable pressure and fluid management are critical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Question\" itemprop=\"mainEntity\" itemscope=\"\"\u003e\n\u003ch3 itemprop=\"name\"\u003e\u003cstrong\u003e3. Can this system be used with glycol solutions?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Answer\" itemprop=\"acceptedAnswer\" itemscope=\"\"\u003e\n\u003cp itemprop=\"text\"\u003eYes. The GL50-H1-1 is designed for glycol-based heating and process systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Question\" itemprop=\"mainEntity\" itemscope=\"\"\u003e\n\u003ch3 itemprop=\"name\"\u003e\u003cstrong\u003e4. Why is low-level control important?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Answer\" itemprop=\"acceptedAnswer\" itemscope=\"\"\u003e\n\u003cp itemprop=\"text\"\u003eLow-level control helps protect equipment by alerting operators when fluid levels become low, reducing the risk of pump damage and operational interruptions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Question\" itemprop=\"mainEntity\" itemscope=\"\"\u003e\n\u003ch3 itemprop=\"name\"\u003e\u003cstrong\u003e5. Is this model suitable for industrial applications?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv itemtype=\"https:\/\/schema.org\/Answer\" itemprop=\"acceptedAnswer\" itemscope=\"\"\u003e\n\u003cp itemprop=\"text\"\u003eAbsolutely. The 55-gallon capacity and automatic feed functionality make it well-suited for commercial, institutional, and industrial facilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eDownload Resources:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eClick \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0428\/8515\/2917\/files\/Wingert_High_Temperature_Glycol_Feed_System_Data_Sheet.pdf?v=1602010393\" title=\"high temperature glycol feeder specification data sheet\" target=\"_blank\" rel=\"noopener\"\u003ehere\u003c\/a\u003e the data sheet\u003c\/p\u003e\n\u003cp\u003eClick \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0428\/8515\/2917\/files\/wingert_glycol_feeder_brochure.pdf?v=1600902444\" title=\"glycol feeder brochure\" target=\"_blank\" rel=\"noopener\"\u003ehere\u003c\/a\u003e for the brochure\u003c\/p\u003e\n\u003cp\u003eClick \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0428\/8515\/2917\/files\/Wingert_Glycol_Feed_Systems_Instruction_Sheet.pdf?v=1600902440\" title=\"glycol feeder OPERATION \u0026amp; MAINTENANCE MANUAL\" target=\"_blank\" rel=\"noopener\"\u003ehere\u003c\/a\u003e for instruction sheet\u003c\/p\u003e","brand":"Bypassfeeder.com","offers":[{"title":"Default Title","offer_id":36635593408661,"sku":"","price":6623.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0428\/8515\/2917\/files\/JL-Wingert-GL50-H1-1-High-Temperature-55-Gallon-Glycol-Feed-System-with-Low-Level-Control.png?v=1774501827","url":"https:\/\/bypassfeeder.com\/products\/j-l-wingert-gl50-h1-1-high-temperature-55-gallon-glycol-feed-system-with-low-level-control","provider":"Bypassfeeder.com","version":"1.0","type":"link"}